Full-surface cold self-adhesive membrane (KSK) for sealing components in contact with the ground against soil moisture and non-pressing water.
The standard-compliant building waterproofing made of a cross-laminated special HDPE carrier film and a sealing and adhesive layer made of bitumen rubber offers the ideal and permanent moisture protection for the building envelope.
DELTA®-THENE can be used in the following areas of application:
Processing
The surface must be smooth, dry, dust-free, clean, pressure-resistant and load-bearing. Mineral surfaces must be pre-treated with a primer DELTA®-THENE GRUNDANSTRICH, DELTA®-THENE KÄLTEGRUNDANSTRICH or DELTA®-THENE GRUND INSIDE before applying DELTA®-THENE. Before laying the surface, all edges, covings etc. need to be prepared with cuts made of DELTA®-THENE or with the prefabricated DELTA®-THENE-BAND T 300/500 in such a way that all critical areas are made of two layers when the laying is complete. The laying of DELTA®-THENE happens track section to track section. Peel off the release paper in the back at the beginning of the track approx. 20 cm and bend it over sharply. Then align and glue on the web. The overlap between the strips must be 10 cm. All overlaps, connections and ends must be carefully reworked and pressed on with a pressure roller.
Material | Cold self-adhesive bitumen rubber as a sealing and adhesive layer with a cross-laminated special HDPE carrier film |
Thickness | approx. 1,5 mm |
Weight | approx. 1,6 kg/m² |
Servicetemperature range | from -30 °C to + 80 °C |
Working temperature | from +5°C to +30°C (air and surface). Up to -5°C with DELTA®-THENE KÄLTEGRUNDANSTRICH (COLD BASECOAT) |
Widths | 1 m |
Roll length | 5 m and 20 m |
Storage | Transport and store upright, store dry and protect from direct sunlight |
Disposal | EWC Code 1 703 02 Asphalt, tar-free |
Packaging | recyclable |
Watertightness (EN 1928, Procedure B) | passed (400 kPa/72 h) |
Reaction to fire (EN 13501-1) | Fire class E |
Tensile strength (EN 12311-1) | Lengthways: approx. 250 N/50 mm |
Crosswise: approx. 250 N/50 mm | |
Tear resistance (nail shaft) (EN 12310-1) | Lengthways: approx. 150 N |
Crosswise: approx. 150 N | |
Flexibility at low temperature (pliability) (EN 1109) | -30 °C |
Sd-value | approx. 150 m |
Application type (DIN SPEC 20000-202) | BA, MSB-nQ |
Water exposure class (DIN 18533) | W1-E (W1.1.-E, W1.2-E) und W4-E |
Room usage class (DIN 18533) | RN1-E bis RN3-E |
Crack class (DIN 18533) | RÜ1-E bis RÜ3-E |
Would you like information on detailed product properties, use cases or other technical topics?
Then feel free to contact our application department on +49 2330 63 578 or atabvf@doerken.de.
Do you have questions about prices, availability or the status of your order?
Our sales service will help you with these matters on +49 2330 63 636 or membranes@doerken.de.